Overview:
(The values in this table are edge-values for the resp. type range. The adjustment range for the power supplies usually is beginning from zero.)

Power supply type range

Design principle

Vmin
Volts
Vmax
Volts
Imin
Amps
Imax
Amps
Pmin
Watts
Pmax
Watts
NTN

Linear regulated power supply with thyristor pre-regulation

6,5 350 0,5 4000 35 100000
NYN

Thyristor regulated power supply

12,5 350 20 4000 7000 100000
               
The following links may be also of interest:
Autoranging Power Supplies:
NCA

Switch mode power supply

55 55 40 160 750 3000
MCA

Switch mode power supply

150 3000 0,75 180 750 9000
Medium Voltage Power Supplies:
MCP

Switch mode power supply

125 2000 0,006 20 35 4200
MYN

Thyristor regulated power supply

650 2000 3 100 7000 70000
Cassettes:
HCE 

Switch mode power supply

125 35000 0,0002 0,25 7 35
               


 
Series NTN ...

Printer friendly data sheet (PDF)

Features:

  • High efficiency
  • Short circuit proof and unlimited operation with full current in short circuit condition
  • voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs
  • Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked
  • 4½ digit DVM for voltage and current (for table-top models)
  • Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals
  • Parallel and series connection possible
  • Suitable for inductive and capacitive loads
  • for 700 W nominal power and higher, limitation of inrush current on switching on
  • Interlock loop to monitor the external load and internal loop as a standard for three phase units
  • Elapsed-hour meter as a standard for three phase units

to top of the page

Function:

The mains voltage is transformed to the appropriate level. On the secondary side of the transformer, a controlled rectifier with thyristors (phase cutting circuit) is installed. The rectified voltage charges a bank of capacitors of the intermediate circuit, from which it is given via a serial regulating transistor and a small LC-filter to the output. By switching-on the thyristors with a distinct delay after each zero-crossing of the sinusoidal voltage, the flow of energy is controlled in a way to have a defined voltage drop at the serial transistor (pre-regulation). The serial transistor defines the final stability of the output voltage (main regulation).

Design:

  • Up to 140 W nominal power ½19" table-top case
  • For 350 W nominal power or higher 19" table-top case
  • 19" Rack-adapters for mounting into a 19" rack are available as accessory
  • For 7 kW nominal power or higher 19" cabinet. Height depending on type. The side covers are detachable, the rear door is lockable.
  • All cabinets are equipped with fork-lift-compatible plinths and removable crane-eyes.
  • Single 19"- cabinets up to  38 HU are are easily transportable by fork-lift.
  • The cooling is carried out via built-in Fans, the output air is derived (type depending) to the rear side or via the top. For units of high output power water cooling can be made. 

Output:

  • Output isolation:
    The output is floating. Operating voltage with respect to earth: ±500 V, either the positive or the negative terminal may be connected to earth. For units equipped with the analogue programming: the "0V" of the analogue programming is connected to the positive output.
  • Output terminals:
    Output terminals are on the rear panel. Up to 20 A output current, 4 mm safety connectors are used. For current up to 300 A - clamps are fitted, for higher currents we use copper bars.

Technical Data:

  • Mains connection:
    up to 1400W nominal power:  230 V ±10% 47 Hz to 53 Hz
    for 2800W and 4200W:  400 V ±10% 47 Hz to 53 Hz, two-phase
    for 7000W and higher  400 V ±10% 47 Hz to 53 Hz, three-phase
 
  • Ambient temperature: 0°C to +40°C

 
  • The following data applies for voltage and current regulation, and refers to the rated value (if not stated otherwise):
    (For explanations please refer to the Terms & Definitions page.)

    Setting range: 

    from approx. 0,1% to 100%

    Reproducibility:

    ±1 x 10-4

    Setting resolution (potentiometer): 

    ±1 x 10-3

    Residual ripple:

    <1 x 10-4pp + 10 mVpp

    Recovery time:
    Voltage control:
    Curent control:

    <50µs for load changes from 10% to 100% or from 100% to 10%
    <500 ms for load changes causing an output change of less than 10% of the rated voltage
    Units with >65V output voltage will switch off for a short time at high and fast load changes.
    Setting time at nominal load:  100 ms to 500 ms for changes of the output voltage from 10% to 90% or 90% to 10%

    Discharging time constant
    for output without load:


    approx. 2sec. to 60sec., depending on type

    Deviation: 
    for ±10% mains voltage variation:
    for no load / full load:
    over 8 h under constant conditions:
    within the temperature range:


    <± 1 x 10-5
    <2 x 10-4
    <±1 x 10-4
    <±1 x 10-4 / K

 

Possible Options:

NTN Data Sheet:

Zur Darstellung muss der ADOBE READER installiert werden!

 

to top of the page

For prices please ask us or one of our representatives.

 


 
Series NYN ...

Printer friendly data sheet (PDF)

Features:

  • Simple construction
  • Extremely robust
  • High efficiency
  • Short circuit proof and unlimited operation with full current in short circuit condition
  • Voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs
  • Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked
  • 3½ digit DVM for voltage and current
  • Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals
  • Limitation of inrush current on switching on
  • Suitable for inductive and capacitive loads
  • Interlock loop to monitor the external load and internal loop as a standard
  • Elapsed-hour meter as a standard

to top of the page

Function:

The mains voltage is transformed to the appropriate level. On the secondary side of the transformer, a controlled rectifier with thyristors (phase cutting circuit) is installed. The rectified voltage is smoothed by a LC - filter.

Design:

  • Depending on Voltage and Power the units are built as single or double 19" cabinets of various height. The side covers are detachable, the rear door is lockable.
  • ll cabinets are equipped with fork-lift-compatible pliths and removable crane-eyes.
  • Single 19"- cabinets up to  37 HU are also suitable for transportation by fork-lift.
  • The cooling is carried out via built-in Fans, the output air is derived (type depending) to the rear side or via the top. 

Output:

  • Output isolation:
    The output is floating. Operating voltage with respect to earth: ±500 V, either the positive or the negative terminal may be connected to earth.
  • Output terminals:
    All output terminals are located at the rear side of the cabinet. For Output current up to 300A feed though terminals are equipped; for higher current, the output is made by copper bars.

Technical Data:

  • Mains connection:
     400 V ±10% 47 Hz to 53 Hz, three-phase
 
  • Ambient temperature: 0°C to +40°C

 
  • The following data applies for voltage and current regulation, and refers to the rated value (if not stated otherwise):
    (For explanations please refer to the Terms & Definitions page.)

    Setting range: 

    from approx. 1% to 100%

    Setting resolution (potentiometer): 

    ±2 x 10-4

    Reproducibility:

    ±1 x 10-3

    Residual ripple:

    <1 x 10-2pp + 100 mVpp

    Recovery time: <100 ms to 500 ms (depending on type) for load variations of  ±10%
    Setting time at nominal load:  <100 ms to 2 sec (depending on type) for changes of the output voltage from 10% to 90% or 90% to 10%

    Discharging time constant
    for output without load:


    approx. 5 sec. to 60 sec., depending on type

    Deviation: 
    for ±10% mains voltage variation:
    for no load / full load:
    over 8 h under constant conditions:
    within the temperature range:


    <±1 x 10-4
    <±1 x 10-3
    <±3 x 10-4
    <±3 x 10-4 / K

 

Possible Options:

NYN Data Sheet:

Zur Darstellung muss der ADOBE READER installiert werden!

 

to top of the page

For prices please ask us or one of our representatives.


Please don't hesitate to contact us, if you don't find for what you are searching. We will be happy, to offer a solution, tailored especially to your needs.

Examples for customer specific solutions

to top of the page

zur deutschen Version

 22.10.12 08:27

Impressum - Legal Notice: 

Diese Seite wird betrieben von der FuG Elektronik GmbH, Am Eschengrund 11, 83135 Schechen.
Geschäftsführer: Dr. Hartmut Simon (Vorsitz), Anton Elsasser.
Telefon +49 8039 40077 0
Telefax +49 8039 40077 99
Registergericht: Traunstein HRB 8638, Umsatzsteuer-Ident-Nr: DE 16 18 91 071.

This page is managed by the FuG Elektronik GmbH, Am Eschengrund 11, 83135 Schechen (Germany).
Board of Directors: Dr. Hartmut Simon (CEO), Anton Elsasser.
Telephone +49 8039 40077 0
Telefax +49 8039 40077 99
Commercial court: Traunstein HRB 8638, VAT NR: DE 16 18 91 071.

Mit Anregungen und Hinweisen zu diesen Seiten wenden Sie sich bitte an :
With your suggestions or comments concerning this pages please contact:
webmaster@fug-elektronik.de 

Trotz sorgfältiger inhaltlicher Kontrolle übernehmen wir keine Haftung für die Inhalte externer Links. Für den Inhalt der verlinkten Seiten sind ausschließlich deren Betreiber verantwortlich. (siehe auch HAFTUNGSAUSSCHLUß)
In spite of thorough check of the contents we do not take over any liability for the contents of external links. For contents of linked websites are responsible  exclusively the persons who running them. (see NON LIABILITY STATEMENT- disclaimer)

Stand: 18. September 2012
©
FuG Elektronik GmbH