High Voltage Power Supplies

Overview:
(The values in this table are edge-values for the resp. type range. The adjustment range for the power supplies usually is beginning from zero.)

Power supply type range

Design principle

Vmin
Volts
Vmax
Volts
Imin
Amps
Imax
Amps
Pmin
Watts
Pmax
Watts
HCP

Switch mode power supply

3500 150000 0,0005 4,5 14 15000
HCH

Switch mode power supply

650 200000 0,0015 75 350 50000
HYN

Thyristor regulated power supply

3500 20000 0,3 20 7000 70000
The following links may be also of interest:
Cassettes:
HCE 

Switch mode power supply

125 35000 0,0002 0,25 7 35
               
Medium Voltage Power Supplies:
MCP

Switch mode power supply

125 2000 0,006 120 14 15000
MYN

Thyristor regulated power supply

650 2000 3 100 7000 70000
Autoranging Power Supplies:
MCA

Switch mode power supply

150 3000 0,75 180 750 9000
Capacitor Charging Power Supplies:
HCK

Switch mode power supply

2000 65000 0,003 20    


 
Series HCP ...

Printer friendly data sheet (PDF)

Features:

  • Compact size and light weight
  • Efficiency approx. 90%
  • For units from 12.5 kV nominal voltage on, all HV components are moulded in (removable) silicon
  • Short-circuit & flashover proof
  • Unlimited operation with rated current in a short-circuit condition
  • Unlimited operation with rated power
  • Voltage and current regulation with automatic sharp transition, indicated by LEDs
  • Adjustable overvoltage protection (limitation of set value)
  • 4½ digit DVM's for voltage and current for all models
  • Voltage and current setting by means of  10-turn potentiometers with precision scale; the adjusting knob can be locked
  • Indication of set point values by means of button for switchover of the displays 
  • Set point adjustment possible with locked output, release of output voltage by means of  "ON" / "OFF" switch
  • Suitable also for inductive and capacitive loads
  • Suitable for photomultipliers

to top of the page

Function:

In principle, the rectified line voltage drives a square wave generator of fixed frequency, whose AC voltage is transformed, rectified and filtered, producing the output voltage. For regulation, the square wave voltage is pulse width modulated.

Low residual ripple of the produced  output voltage together with a high stability, good regulation dynamics and in the same time  only low stored energy will be achieved due to a high switching frequency.

Design:

  • ½19" or 19" table-top case (depending on output voltage and power)
  • 19" Rack-adapters for mounting into a 19" rack are available as accessory

Output:

  • Output isolation:
    The required output polarity has to be stated with the order. One output terminal each leads the high voltage, the  "0V" terminal is connected firmly to earth. If required, the "0V" terminal can be made floating against earth up to ± 300V. A polarity reversal switch is optionally available.
  • Output terminals:
    All output terminals are located at the rear side of the unit. High voltage connectors with the appropriate dielectric strength are delivered with the power supply.
    For nominal voltage of 65 kV and higher the HV- plug will be delivered ready mounted to 3m cable.
     

Technical Data:

  • Mains connection:
    up to 1400W nominal power:  230 V ±10% 47 Hz to 63 Hz
    for 2800W and higher:  400 V ±10% 47 Hz to 63 Hz, three-phase
 
  • Ambient temperature: 0°C to +40°C

 
  • The following data applies for voltage and current regulation, and refers to the rated value (if not stated otherwise):
    (For explanations please refer to the Terms & Definitions page.)

    Setting range: 

    from approx. 0,1% to 100%

    Reproducibility:

    ±1 x 10-4

    Setting resolution (potentiometer): 

    ±1 x 10-3

    Residual ripple:

    <1 x 10-4pp + 50 mVpp, typ. 5 x 10-5pp

    Recovery time:
    Voltage control:
    Curent control:

    <1 ms for load changes from 10% to 100% or from 100% to 10%
    <10 ms for load changes causing an output change of less than 10% of the rated voltage
    Setting time at nominal load:  <500 ms for changes of the output voltage from 10% to 90% or 90% to 10%

    Discharging time constant
    for output without load:


    approx. 2sec. to 10sec., depending on type

    Deviation: 
    for ±10% mains voltage variation:
    for no load / full load:
    over 8 h under constant conditions:
    within the temperature range:


    <± 1 x 10-5
    <2 x 10-4
    <±1 x 10-4
    <±1,5 x 10-4 / K

 

Possible Options:

Coarse/fine-potentiometer (99% / 1%) for more accurate adjustment of voltage and / or current
Analogue programming
Analogue programming, floating
Computer interface - IEEE 488, RS 232, RS 422, USB, LAN (Ethernet), Profibus DP (more on request)
electronically controlled polarity reversal switch (Push button at the front plate - remotely controllable when ordered with a programming or interface) available up to 35 kV (by request also for higher voltage). Please specify the output polarity, when ordering without polarity reversal switch.
Lower ripple
Higher stability
Lower stored energy
Power limitation

More options and special solutions on request. Some options may involve changes to the description of the unit - especially concerning the mechanical design.

HCP Data Sheet:

Zur Darstellung muss der ADOBE READER installiert werden!

 

to top of the page

For prices please ask us or one of our representatives.

3) Mains connection three-phase

HCP units with 65 kV and polarity reversal may be of bigger dimensions than above stated .


 
Series HCH ...

Printer friendly data sheet (PDF)

Features:

  • Efficiency approx. 90%
  • Short-circuit & flashover proof
  • In units up to 20 kV nominal voltage the HV-components are isolated in air. From 35 kV on the isolation is with oil.
  • Unlimited operation with rated current in a short-circuit condition
  • Unlimited operation with rated power
  • Voltage and current regulation with automatic sharp transition, indicated by LEDs
  • 3½ digit DVM's for voltage and current
  • Limitation of inrush current on switching on
  • Voltage and current setting by means of  10-turn potentiometers with precision scale; the adjusting knob can be locked
  • Interlock loop to monitor the external load and internal loop as a standard

to top of the page

Function:

In principle, the rectified line voltage drives a square wave generator of fixed frequency, whose AC voltage is transformed, rectified and filtered, producing the output voltage. For regulation, the square wave voltage is pulse width modulated.

Design:

  • Depending on Voltage and Power the units are built as single or double 19" cabinets, or as a oil- filled HV container with the power electronics on the top or in a seperate rack.

Output:

  • Output isolation:
    The required output polarity has to be stated with the order. One output terminal each leads the high voltage, the  "0V" terminal is connected firmly to earth. If required, the "0V" terminal can be made floating against earth up to ± 50V. A polarity reversal switch is optionally available.
  • Output terminals:
    All output terminals are located at the rear side of the cabinet or at the top of the HV container. 
    High voltage connectors with the appropriate dielectric strength are delivered with the power supply.
    For nominal voltage of 65 kV and higher the HV- plug will be delivered ready mounted  to 10m cable.
     

Technical Data:

  • Mains connection:
    up to 1400W nominal power:  230 V ±10% 47 Hz to 63 Hz
    for 2800W and higher:  400 V ±10% 47 Hz to 63 Hz, three-phase
 
  • Ambient temperature: 0°C to +40°C

 
  • The following data applies for voltage and current regulation, and refers to the rated value (if not stated otherwise):
    (For explanations please refer to the Terms & Definitions page.)

    Setting range: 

    from approx. 0,1% to 100%

    Reproducibility:

    ±1 x 10-4

    Setting resolution (potentiometer): 

    ±1 x 10-3

    Residual ripple:

    <2 x 10-3pp + 50 mVpp

    Recovery time:
    Voltage control:
    Curent control:

    <1 ms for load changes from 10% to 100% or from 100% to 10%
    <10 ms for load changes causing an output change of less than 10% of the rated voltage
    Setting time at nominal load:  <100 ms for changes of the output voltage from 10% to 90% or 90% to 10%

    Discharging time constant
    for output without load:


    approx. 1sec. to 10sec., depending on type

    Deviation: 
    for ±10% mains voltage variation:
    for no load / full load:
    over 8 h under constant conditions:
    within the temperature range:


    <± 1 x 10-4
    <5 x 10-4
    <±2 x 10-4
    <±1,5 x 10-4 / K

 

Possible Options:

HCH Data Sheet:

Zur Darstellung muss der ADOBE READER installiert werden!

 

to top of the page

For prices please ask us or one of our representatives.

3) Mains connection three-phase
*) The dimensions and weights are valid for the HV-container with the power part mounted on the top, The values stated here are not binding.
**) The dimensions are valid for the power part, the HV-container is placed in a separate oil-filled HV-container.  Weight: Power part / High voltage container.

 
 
Series HYN ...

Printer friendly data sheet (PDF)

Features:

  • Simple construction
  • Extremely robust
  • High efficiency
  • Short circuit proof and unlimited operation with full current in short circuit condition
  • Voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs
  • Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked
  • 3½ digit DVM for voltage and current
  • Limitation of inrush current on switching on
  • Suitable for inductive and capacitive loads
  • Interlock loop to monitor the external load and internal loop as a standard
  • Elapsed-hour meter as a standard

to top of the page

Function:

The mains voltage is transformed to high voltage potential. Either on the primary side or on the secondary side, a phase cutting circuit with thyristors is installed. The rectified voltage is smoothed by a LC - filter.

Design:

  • Depending on Voltage and Power the units are built as single or double 19" cabinets of various height. The side covers are detachable, the rear door is lockable.
  • ll cabinets are equipped with fork-lift-compatible pliths and removable crane-eyes.
  • Single 19"- cabinets up to  37 HU are also suitable for transportation by fork-lift.
  • The cooling is carried out via built-in Fans, the output air is derived (type depending) to the rear side or via the top. 

Output:

  • Output isolation:
    The required output polarity has to be stated with the order. One output terminal each leads the high voltage, the  "0V" terminal is connected firmly to earth.  A polarity reversal switch is optionally available.
  • Output terminals:
    All output terminals are located at the rear side of the cabinet. For Output current up to 10A high voltage connectors with the appropriate dielectric strength are installed. Mating connectors are delivered with the power supply.

Technical Data:

  • Mains connection:
     400 V ±10% 47 Hz to 53 Hz, three-phase
 
  • Ambient temperature: 0°C to +40°C

 
  • The following data applies for voltage and current regulation, and refers to the rated value (if not stated otherwise):
    (For explanations please refer to the Terms & Definitions page.)

    Setting range: 

    from approx. 1% to 100%

    Setting resolution (potentiometer): 

    ±2 x 10-4

    Reproducibility:

    ±1 x 10-3

    Residual ripple:

    <1 x 10-2pp + 100 mVpp

    Recovery time: <100 ms to 500 ms (depending on type) for load variations of  ±10%
    Setting time at nominal load:  <100 ms to 2 sec (depending on type) for changes of the output voltage from 10% to 90% or 90% to 10%

    Discharging time constant
    for output without load:


    approx. 5 sec. to 60 sec., depending on type

    Deviation: 
    for ±10% mains voltage variation:
    for no load / full load:
    over 8 h under constant conditions:
    within the temperature range:


    <±1 x 10-4
    <±1 x 10-3
    <±3 x 10-4
    <±3 x 10-4 / K

 

Possible Options:

HYN Data Sheet:

Zur Darstellung muss der ADOBE READER installiert werden!

 

to top of the page

For prices please ask us or one of our representatives.

Please don't hesitate to contact us, if you don't find for what you are searching. We will be happy, to offer a solution, tailored especially to your needs.

Examples for customer specific solutions

to top of the page

zur deutschen Version

 11.03.13 10:55

Impressum - Legal Notice: 

Diese Seite wird betrieben von der FuG Elektronik GmbH, Am Eschengrund 11, 83135 Schechen.
Geschäftsführer: Dr. Hartmut Simon (Vorsitz), Anton Elsasser.
Telefon +49 8039 40077 0
Telefax +49 8039 40077 99
Registergericht: Traunstein HRB 8638, Umsatzsteuer-Ident-Nr: DE 16 18 91 071.

This page is managed by the FuG Elektronik GmbH, Am Eschengrund 11, 83135 Schechen (Germany).
Board of Directors: Dr. Hartmut Simon (CEO), Anton Elsasser.
Telephone +49 8039 40077 0
Telefax +49 8039 40077 99
Commercial court: Traunstein HRB 8638, VAT NR: DE 16 18 91 071.

Mit Anregungen und Hinweisen zu diesen Seiten wenden Sie sich bitte an :
With your suggestions or comments concerning this pages please contact:
webmaster@fug-elektronik.de 

Trotz sorgfältiger inhaltlicher Kontrolle übernehmen wir keine Haftung für die Inhalte externer Links. Für den Inhalt der verlinkten Seiten sind ausschließlich deren Betreiber verantwortlich. (siehe auch HAFTUNGSAUSSCHLUß)
In spite of thorough check of the contents we do not take over any liability for the contents of external links. For contents of linked websites are responsible  exclusively the persons who running them. (see NON LIABILITY STATEMENT- disclaimer)

Stand: 18. September 2012
©
FuG Elektronik GmbH