FuG Elektronik offers a wide range of accessories for power supplies:

For all FuG - table- top- units we offer rack- adapter- sets to fit them into 19"- systems. Adapter- sets are available from 2 till 9 units height and for units with 19" width as well as for ½19"- units.

Rack Adapter set for 19"- unit
Rack Adapter set for one ½19"- unit with ½19" blank panel
Rack Adapter set for two ½19"- units


For our cassette power supplies series HCE we have 19" - frames, for HCN7E a table-top case is available.


To operate a power supply at high voltage potential, we offer isolating transformers:

(Please do this with our power supplies only after consulting us and be careful to keep the appropriate safety measures.)

Function:

High voltage isolating transformers are used to provide mains supply to loads, located at high voltage potential. The primary winding is earthy.

Features:

  • Compact size
  • Moulded in artificial resin
  • Low capacity
  • Double screened

Technical data:

  • Input voltage: 230 V 47 - 63 Hz
  • Output voltage: 230 V 47 - 63 Hz
  • Isolation: primary / secondary: 50 kV DC (other isolation voltage on request)
  • Test voltage: 75 kV DC for 1 min.
  • Test voltage between primary winding, primary screen and core: 2.5 kV AC
  • Test voltage between secondary winding and secondary screen: 2.5 kV AC

Mechanical design:

Core and windings are completely moulded in artificial resin with isolating cross-pieces between the connections. Attachment at the bottom with 4 x M8 female thread.

Type Power Dimensions
[LxWxH]
Weight approx.
HTS100 -50100VA165 x 160 x 220mm15kg
HTS500 -50500VA210 x 200 x 230mm21kg
HTS1000 -501000VA210 x 200 x 240mm25kg
HTS2000 -502000VA252 x 252 x 260mm40kg
HTS3000 -503000VA252 x 250 x 270mm43kg

Top

Connection:

Primary and secondary on M6 threaded studs. Screens on isolated wire on the top.

  • Different voltages
  • Different isolating voltages
  • Higher powers
  • Three-phase versions
  • Build-in housing

For all our power supplies you can get the appropriate cables:

Type Construction
RG58 Diameter in mm:
Capacitance / m:
101 pF
Impedance:
50 Ohm
Ambient temp.:
-50°C...+80°C
Bending radius:
10 cm mehrm. / 2,5 cm einm.
Max. current:
10 A
RG58 mit Bemassung
Operating Voltage: max. 10 kV DC
Mating Connector | Operating Voltage: SHV | 6,5 kV
130660 Diameter in mm:
Capacitance / m:
82,7 pF
Impedance:
70 Ohm
Ambient temp.:
-5°C...+85°C
Bending radius:
11 cm mehrm. / 3 cm einm.
Max. current:
4 A
130660 mit Bemassung
Operating Voltage: max. 30 kV DC
Mating Connector | Operating Voltage: HS21, F3415 | 20 kV
RG 11 Diameter in mm:
Capacitance / m:
68 pF
Impedance:
75 Ohm
Ambient temp.:
-50°C...+80°C
Bending radius:
20 cm mehrm. / 5 cm einm.
Max. current:
6 A
RG11 mit Bemassung
Operating Voltage: max. 50 kV DC
Mating Connector | Operating Voltage: F 3430 | 35 kV
C 2124 Diameter in mm:
Capacitance / m:
99 pF
Impedance:
61 Ohm
Ambient temp.:
-50°C...+60°C
Bending radius:
15,2 cm mehrm.
Max. current:
27 A
C 2124 mit Bemassung
Operating Voltage: max. 100 kV DC
Mating Connector | Operating Voltage: HTC65 | 65 kV , HVS 100 | 100 kV
C 2121 Diameter in mm:
Capacitance / m:
95 pF
Impedance:
59 Ohm
Ambient temp.:
-50°C...+60°C
Bending radius:
21,6 cm mehrm.
Max. current:
30 A
C 2121 mit Bemassung
Operating Voltage: max. 150 kV DC
Mating Connector | Operating Voltage: Special plug, only available complete with cable
C 2134 Diameter in mm:
Capacitance / m:
102 pF
Impedance:
64 Ohm
Ambient temp.:
-50°C...+60°C
Bending radius:
25,4 cm mehrm.
Max. current:
55 A
C 2134 mit Bemassung
Operating Voltage: max. 200 kV DC
Mating Connector | Operating Voltage: Special plug, only available complete with cable

Top

Normally the appropriate output connectors are supplied with each unit. If you need more of them, you can order additionally connectors. If the sockets are also needed, please ask us. Click here for information about cable and connector assembling. The following table shows the allocation of power supply types and HV connectors:

Power Supply Model Plug Type
and Quantity in scope of delivery
Material
Number
Mating
Cable
Remarks
MYN 7000-650   SHV Cable Jack2 03 01 04 11 05 RG 58 -
MYN 7000-1250toMYN 14000-1250 SHV Cable Jack2 03 01 04 11 05 RG 58 -
MYN 7000-2000toMYN 21000-2000 SHV Cable Jack2 03 01 04 11 05 RG 58 -
HYN 7000-3500toHYN 35000-3500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HYN 7000-6500toHYN 70000-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HYN 7000-12500toHYN 50000-12500 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HYN 7000-20000toHYN 50000-20000 F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCE 7-1250toHCE 7-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCE 7-12500undHCE 7-20000 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCE 7-35000   F 3430 AG 10,21 03 01 04 03 56 130 660 -
HCE 35-1250toHCE 35-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCE 35-12500undHCE 35-20000 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCE 35-35000   F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCE 140-1250toHCE 140-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCE 140-12500undHCE 140-20000 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCE 140-35000   F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCE 350-1250toHCE 350-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCE 350-12500undHCE 350-20000 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCE 350-35000   F 3430 AG 10,21 03 01 04 04 55 RG 11 -
MCA 750-1500toMCA 3000-1500 SHV Cable Jack2 03 01 04 11 05 RG 58 -
MCA 750-3000toMCA 3000-3000 SHV Cable Jack1 03 01 04 11 05 RG 58 -
MCP 14-650toMCP 4200-650 SHV Cable Jack2 03 01 04 11 05 RG 58 -
MCP 14-1250toMCP 4200-1250 SHV Cable Jack2 03 01 04 11 05 RG 58 -
MCP 14-2000toMCP 4200-2000 SHV Cable Jack2 03 01 04 11 05 RG 58 -
HCP 14-3500toHCP 4200-3500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCP 14-6500toHCP 4200-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCP 14-12500toHCP 4200-12500 HS211 03 01 04 04 25 130 660 -
HCP 14-20000toHCP 4200-20000 HS211 03 01 04 04 25 130 660 -
HCP 35-35000toHCP 4200-35000 F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCP 35-65000toHCP 2800-65000 HVS 651 03 01 04 05 70 C 2124 3m cable included
HCP 140-100000toHCP 1400-100000 HVS 1001 03 01 04 06 05 C 2124 3m cable included
HCP 140-150000toHCP 700-150000 HVS 1501 03 01 04 06 55 C 2121 3m cable included
HCH all models from 650V to 6500V; max. 10A SHV Cable Jack1 03 01 04 11 05 RG 58 3m cable included
HCH all models 12500V F 3415 AG 6,21 03 01 04 03 56 130 660 3m cable included
HCH all models 20000V und 35000V F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCH all models 65000V HVS 651 03 01 04 05 70 C 2124 10m cable included
HCH all models 100000V HVS 1001 03 01 04 06 05 C 2124 10m cable included
HCH higher voltages To be defined1 xx xx -
HCB 1,4-1250toHCB 70-6500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCB 14-12500toHCB 140-12500 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCB 20-20000toHCB 200-20000 F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCK 100-2000toHCK 10000-2000 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCK 20000-2000 To be defined1 xx xx -
HCK 100-3500toHCK 10000-3500 SHV Cable Jack1 03 01 04 11 05 RG 58 -
HCK 20000-3500 To be defined1 xx xx -
HCK 100-6500toHCK 10000-6500 F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCK 20000-6500 F 3430 AG 10,21 03 01 04 04 55 RG 11 -
HCK all models 12500V F 3415 AG 6,21 03 01 04 03 56 130 660 -
HCK all models 20000V F 3415 AG 10,21 03 01 04 04 55 RG 11 -
HCK all models 35000V S 150 Teflon1 03 01 04 05 56 C 2032
SNJ
-
HCK all models 65000V HVS 65 Teflon1 03 01 04 05 69 C 2184 3m cable included (>5kJ 10m)

Top

SHV Cable Jack


F 3415 AG 6,2


HS21


F 3430 AG 10,2


S 130/S150, HVS 65 - HVS 150